of the rover, you will then be allowed to change the storage
medium on the

Recording tab. Don’t forget to re-enable the

Record raw data for post-processing function afterwards.

Advanced tab: This tab contains a single parameter. When
Use RTCM data for coordinate transformation is activated, the
rover will provide position solutions in the same
coordinate system as the one used by the base. This will
be effective if the rover receives the definition of this
coordinate system from the base through RTCM message
types 1021 to 1023. SAPOS networks for example deliver
such messages.

Troubleshoot tab: For maintenance purposes, technical
support may ask you to use this tab. The

Enable debug file

output option should always be inactive in normal
conditions of use.

• Tap

OK to complete the rover configuration step. Tap OK

again to let the receiver operate as an RTK rover.

NOTE: The auto-dial function attached to the internal
modem has been deactivated intentionally to reduce the
cost of your mobile communications. This means that
every time you turn off the modem when you quit ProMark
Field, you will have to re-activate the connection from the
Link tab before you can start a new working session.
Conversely, if you quit ProMark Field and you choose to
keep the modem turned on, the connection will still be
active next time you start a new working session with
ProMark Field.

Logging Points

• Set up the rover as explained in Choosing the Survey Type

and Mode on page 32.

• Turn on the receiver, run ProMark Field and create a job

as explained in Creating a New Job on page 11.

• On the

Options menu, select “Stop & Go Kinematic” and

“Real-time” on the

Survey tab, then tap OK.

• Think about which initialization method you will be using

at the beginning of the project and take the corresponding
steps:

On the Fly: Nothing special needs to be done.

From Known Point: Go to the known point and place

the rover antenna exactly over this point.

From Bar: Go to the base (fitted with the initializer bar)

and place the rover antenna at the free end of the
initializer bar.