Performing a traverse adjustment – Spectra Precision Survey Pro v4.6 Ranger User Manual User Manual

Page 186

Advertising
background image

User’s Manual – Conventional Mode

176

Performing a Traverse Adjustment

1. Tap Adjust , Traverse Adjust from the

Main Menu.

2. Use the Tap Polylines… or To/From…

button to select the polyline or points that

define your traverse, which should be in
the same order that the traverse points

were collected.

3. Select the appropriate checkboxes to define

the type of adjustment(s) to perform and

what will be adjusted.

4. Tap Next > to continue to the next screen.

The screen that opens will depend on the

selections made from the main screen.

5. If an angle adjustment is being performed,

the screen shown here will open. Enter the

closing angle for the traverse in the form of
an angle-right.

6. Tap Next > to open the next screen of the

adjustment wizard.


7. If a Compass Rule adjustment is being performed, the screen

shown here will open. Select Closed Traverse if you are adjusting

a closed traverse or select Close to Known Location if you are
adjusting an open traverse and closing to a known point or

location. A closing location can be defined by an existing point or
known coordinates by toggling the Point / Location button
accordingly.