Specifications

Power: 15‐24 VDC/200mA (customer supplied) 

Sensor/Monitor Frequency Range: 0‐4000 Hz 

Analog Output 4‐20 mA: 16‐bit isolated loop powered 2‐wire output; 12‐27 VDC loop 

supply; max. load impedance = 500 Ohm.@ 27V; max. load impedance = 250 Ohm.@ 12V 

Two Opto‐Isolated Open‐Collector Outputs: 5‐30 VDC rating, 50 mA Max. (minimum load 

impedance required = 600 Ohm @ 30 VDC) 

Opto‐Isolated Reset Input: 5‐30 VDC Input, 3.3Kohm Impedance 

Temperature Ratings: ‐20 to 60°C (‐4 to 140°F) ambient; 85°C (185°F) max. fluid 

temperature (standard); 175°C (350°F) max. fluid temperature (RT‐15C) 

Enclosure Certification:  NEMA 4X 

Connection: screw terminal strips; ¾" NPT conduit entrance 

Sensor Noses 

A variety of sensor noses is available to provide compatibility with AW Gear Meters flowmeters.  See 
chart below. 

RT‐Ex Model 

Sensor Nose 

RT‐15A  

MAG‐PB sensor (standard) for JV‐CG/KG, HPM and TRG series flowmeters. 

RT‐15B 

IR‐PB sensor for JVK series flowmeters. 

RT‐15C 

CP‐30 high temp sensor (to 350°F) for JVM‐CG/KG, JVS‐CG/KG HPM series meters. 

RT‐15D  

MG‐300 sensor for TR series turbine flowmeters. 