RT‐15 Flow Monitor

 

Operation and Programming Manual 

 

 

 

22 

      
 

TOTAL A Rollover 

RT‐15 JOB totals rollover to zero when the total reaches a value of 999999 regardless of the decimal 
location. When a JOB total rolls over or is reset, the device adds the contents of the JOB total in memory 
to the GRAND total.  

GR TOTAL A Rollover 

To allow retention of the largest possible GRAND total before data loss, after reaching a value of 999999 
regardless of decimal location, a floating decimal feature automatically reduces decimal resolution by a 
maximum of two decimal places before rolling over to zero and losing the total. For example, for a KFT 
with four decimal places, the GRAND total reaches 9999.99 instead of 99.9999 before resetting to zero.  

Total Mode Programming 

Program the Total parameters from the TOTAL A display screen.  

1. With the cover open, use the MODE/DN button (or magnetic switch) to select the TOTAL A 

display. 

2. Press and hold the ENT button (or maintain the ENT magnetic switch).  
3. The display first shows a P in the lower left‐hand corner and then displays the first program 

variable for the TOTAL display mode.  

You can access two parameters from the TOTAL screen: 

 KFT A VALUE 

 ENG UNITS A 

KFT A VALUE 

This is a scaling factor to display totals in a desired engineering unit such as gallons. The KFT value you 
enter from the TOTAL A screen also determines the decimal resolution of the total display. The RT‐15 
calculates the KFT using the K‐factor of the transducer being monitored. The K‐factor is the number of 
impulses per engineering unit established by the transducer manufacturer or by a calibration test. The 
AW Gear Meters Calibration sheet stipulates the K‐factor and recommended KFT. 

 

Initial default is: 10000.   (displays total pulses with no decimals) 

The KFT factor is calculated using the following formula:  

KFT= 10000/K‐FACTOR 

where: 

 10000 is a constant  
 K‐FACTOR is the average number of pulses per desired engineering unit that the transducer 

produces. 