Rt‐15 flow monitor – AW Gear Meters RT-15 User Manual

Page 29

Advertising
background image

RT‐15 Flow Monitor

 

Operation and Programming Manual 

 

 

 

28 

      
 

reverts to the Job Total (TA) display). You can reset Total A from this display using the RESET/UP button 
(or magnetic switch).  

 

 

 

 

The RAT A TOT A display is only for viewing the rate and total simultaneously and has no programming 
function. Program Rate and Total variables from the RATE A

 GT

 or RATE A

 PL

 and TOTAL A screens 

respectively. 

BATCH TOTAL Display Mode 

The BATCH TOTAL displays the JOB A total and the S1 and S2 total limit activation levels. When the RT‐
15 is programmed for BATCH TOTAL operation, both limits are assigned as TOTAL A limits based on the 
KFT, decimal point, and engineering units. The TOTAL limit activation levels are displayed unless 
assigned to another function. If so, the S1 or S2 display reads XXXX to indicate that it is not assigned to 
JOB A TOTAL function.   




BATCH TOTAL Programming

 

Use the BATCH TOTAL program mode to dedicate quickly both limits as total limits and program the 
values at which the limits (S1 and S2) activate. Program BATCH TOTAL limits from The BATCH TOTAL 
display. Use the MODE/DN button (or magnetic switch) to get there.  Press and hold the ENT button (or 
maintain the ENT magnetic switch). The display first shows a P in the lower left‐hand corner and then 
highlights the first limit assignment S1 indicated with a blinking cursor. Entering a value assigns the limit 
as a total limit based on the KFT, decimal location and KFT engineering units. Select the digit to edit 
using the SEL button (or magnetic switch). Use the UP or DN button (or magnetic switch) to increase or 
decrease the variable value.  When the desired value displays, use the ENT button (or magnetic switch) 
to store the programmed value and move the cursor to S2. Select the digit to edit using the SEL button 
(or magnetic switch). Use the UP or DN button (or magnetic switch) to increase or decrease the value.  
When the desired value displays, use the ENT button (or magnetic switch) to store the value and exit the 
BATCH TOTAL mode.  

If either limit is already assigned to a function other than TOTAL A, the RT‐15 responds by asking “Limit 
mode different, want to change it?” Use the SEL button (or magnetic switch) to toggle an “N” or “Y” 