AW-Lake Company 8809 Industrial Drive, Franksville, WI 53126  web: www.aw-lake.com

 Tel: 262-884-9800  Fax: 262-884-9810  Email: [email protected]

REV. 1.3 LLC-E-BA Manual rev 3.3.10.DOC

13

PROGRAM Mode

The Program Mode is used to enter, edit, or examine the programmed variables and batch quantities.
Program variables must be entered before the batch programming. The RUN/PROGRAM key-
switch must be in the vertical PROG position to enter the PROGRAM mode.

Default Variables

The LLC-BA has been programmed by AW Company with either the default variable values listed in
Table 1 or with values determined specifically for the supplied flow transmitter and the requested
engineering units. If the variable values are the defaults shown here, follow the directions in the next
sections to determine and enter the variable values for your application. Record your entries in this
manual in the space provided in Table 1. If the variable values found in the LLC-P are not the
default values shown below, these programmed values will in most cases be the optimum values
and no editing will be required.

Batch numbers 1 through 9 will contain the default values shown in Table 1 and will require editing
for your specific application. Record your entries in this manual in the space provided in Table 1.

Variable Name

Default Value

Programmed Value

DELAY

00000.50

PRECUT

0000000.

0-SET mA.s

0000x.xx

GTIME[s]

0000001

KFR

00100.00

DP KFR

00000.00

E-UNITS KFT

hz

KFT

0010000.

DP KFT

0000000.

E-UNITS KFT

pul

Batch Number

Default Value

Programmed Value

BATCH #1

100.00

BATCH #2

000.00

BATCH #3

000.00

BATCH #4

000.00

BATCH #5

500.00

BATCH #6

000.00

BATCH #7

000.00

BATCH #8

000.00

BATCH #9

900.00

Table 1