Input/Output Wiring Terminal Connections


TERMINAL 1

mA. [+] - Positive, isolated internally loop powered 4-20mA. output

TERMINAL 2

mA. [- ] - Negative, isolated internally loop powered 4-20mA. output

TERMINAL 3

Remote Start/Stop, to remote momentary contact (optional)

TERMINAL 4

Remote Start/Stop, to remote momentary contact (optional)

TERMINAL 5

Relay 2 N.C. Contact - No connection (typical)

TERMINAL 6

Relay 2 N.O. Contact - to High Flow Solenoid (if used)

TERMINAL 7

RELAY 2 COMMON - Connect to TERMINAL 11(110VAC)

TERMINAL 8

Relay 1 N.C. Contact - No connection (typical)

TERMINAL 9

Relay 1 N.O. Contact - to Low Flow Solenoid

TERMINAL 10

RELAY 1 COMMON - Connect to TERMINAL 11(110VAC)

TERMINAL 11

110VAC (GND) - to Terminals 7 & 10

TERMINAL 12

110VAC (NEUTRAL) - to Low & High Flow Solenoids

TERMINAL 13

110VAC - GND (Line Cord)

TERMINAL 14

110VAC - NEUT (Line Cord)

TERMINAL 15

110VAC - HOT (Line Cord)