Introduction

Mounted in a pre-wired NEMA 12 industrial enclosure, the LLC-BA Batch Controller provides
accurate and repeatable batch control, stores up to nine different programmable batch quantities,
and is a rate, total or batch indicator.
The LLC-BA controls batch operation with relay contacts to initiate and stop the flow. Two
separate relay outputs allow the control of two solenoids with different flow rates providing a slow
stop/start of the flow. The LLC-BA activates the low flow solenoid on the START input and after
a programmed variable DELAY, the high flow solenoid is activated producing a combined high
flow rate. The high flow solenoid is deactivated before the batch amount has been reached by
means of the PRECUT variable reducing the flow for a slow stop. The low flow solenoid is de-
activated when the programmed batch amount is reached.
The LLC-BA compensates for a valve or fluid delay in the batch system with the Automatic Over-
run Compensation feature. The A.O.C. feature detects any overrun and the LLC-BA anticipates
and corrects for the delay on the next batch. This feature is always active and adapting
continuously to correct for long-term changes in valves and fluid characteristics.

Features

*

87C51FB Microprocessor based design

*

Dust-proof LEXAN front panel and display window

*

Flowmeter connection via MIL-C-5015 style connector

*

Long Life EEPROM variable and total value storage

Technical Data









Enclosure:
NEMA 12 & 13

Sensor Supply Output:
Approx. 20mA @ 18VDC

Power Supply:
110VAC 60Hz

Sensor Input:
Voltage triggered,
2.00 Vp-p min., 0 - 4KHz, 10K

Ω imp.

Display:
LCD, 16 character alpha-numeric,
.35 inch character height

Main Board:
87C51FB

μProcessor,

EEPROM memory

Two Form C Relay Outputs:

Relay Contact Ratings

Resistive Load

DC: 60W AC:
125VA

Inductive Load

DC: 30W AC:
60VA
220V DC, 250V AC
2A

DC: 30V, 2A AC:
110V, 0.5A

Resistive Load

Inductive Load

DC: 30V, 1A AC:
110V, 0.3A

Maximum
Switched
Power

Maximum Switch Voltage
Maximum Switch Current

Rated
Load

Advertising