Entering/Editing the Variables


The LLC-BA must be in the program mode to enter the variables. To enter the Programming Mode,
turn the RUN/PROG key switch to the vertical PROG position. To enter or edit the variables, press
and hold the [PROG]-key (

ENT

). The display will start flashing PROGRAMMING ????. When the

display stops flashing, release the [PROG]-key (

ENT

). The LLC will now display the first variable,

DELAY, and is ready for the user to enter, edit or examine the variables. After each variable is
viewed/edited and the displayed value is stored, the LLC advances to the next variable.


DELAY
- This variable sets the delay time for Relay2 (high flow solenoid output) relative to the
START input. Typical delays are from 0.00 to 4.00 seconds. This function is used in slow start
applications where Relay1 (low flow solenoid output) is energized immediately at a START input and
Relay2 (high flow solenoid output) is turned on after the DELAY time.

Factory default is 00000.50 seconds


Press and hold the (UP) or (DN)-key to increment or decrement the variable value. To increase
the increment or decrement rate, while holding the (UP) or (DN)-key, press and hold the (SEL)-key
for medium rate or the (ENT)-key for maximum rate. When the desired value is displayed,
press the (ENT)-key to store the programmed value and advance to the next variable.
NOTE: Always release (SEL) or (ENT)-key before releasing the (UP) or (DN)-key or the LLC will
proceed to next variable leaving the last variable with an unpredictable value.


PRECUT
- This variable sets the batch quantity remaining when Relay2 (high flow solenoid output)
is turned off. This variable is programmed using the KFT engineering units and decimal point. This
function is used in slow stop applications where Relay2 (high flow solenoid output) is turned off a
PRECUT amount before the total batch quantity is reached and Relay1 (low flow solenoid output)
remains energized until the batch quantity is reached.

Factory default is 0000000 pulses


Press and hold the (UP) or (DN)-key to increment or decrement the variable value. To increase
the increment or decrement rate, while holding the (UP) or (DN)-key, press and hold the (SEL)-key
for medium rate or the (ENT)-key for maximum rate. When the desired value is displayed,
press the (ENT)-key to store the programmed value and advance to the next variable.
NOTE: Always release (SEL) or (ENT)-key before releasing the (UP) or (DN)-key or the LLC will
proceed to next variable leaving the last variable with an unpredictable value.