Section 3 programming for dact-ud2, Programming for dact-ud2 – Fire-Lite DACT-UD2 Digital Alarm Communicator/Transmitter User Manual

Page 18

Advertising
background image

Programming for DACT-UD2

18

DACT-UD2 Communicator PN 53037:B 4/01/08

SECTION 3

Programming for DACT-UD2

3.1 Programming the MS-9600LS Fire Alarm Control Panel

Refer to the MS-9600LS Manual programming section for general programming
information. To program the MS-9600LS FACP for use with the DACT-UD2:

1. Press the Enter or Mode key to display the Read Status/Programming screen

2. Press 2 to access Programming

3. Enter the Master level password

4. Press the down arrow key twice to view the screen with the Option Modules

choice

5. Press 3 for Option Modules to access the Option Modules screen as shown to the

left

6. Program the FACP for use with the DACT-UD2 using the following procedure

NOTICE TO USERS, INSTALLERS, AUTHORITIES HAVING JURISDICTION

AND OTHER INVOLVED PARTIES

This product incorporates field-programmable software. In order for the product to comply with the requirements in ANSI/UL
864, Standard for Control Units and Accessories for Fire Alarm Systems, certain programming features or options must be lim-
ited to specific values or not used at all as indicated below:

Program feature

or option

Permitted in

ANSI/UL 864?

(Y/N)

Possible settings

Settings permitted

in ANSI/UL 864

Trouble Call Limit

N

Refer to "Trouble Call Limit (Dialer Runaway Prevention)"
on page 22.

Trouble Call Limit = 0 (factory default): unlimited

calling to Central Station for any trouble condition

Trouble Call Limit = 1 - 99: limits call for each unique

trouble to from 1 to 99 within a 24 hour period

Trouble Call Limit =
0 for unlimited

Central Station

trouble calls

Remote Download

Y

Refer to

Remote Download - Proprietary No

Remote Download - Proprietary Yes

Remote Download
Proprietary Yes for
Proprietary
Installations Only