Caution – HT instruments HT7051 User Manual

Page 11

Advertising
background image

HT2055

EN - 10

5.1.3 Synchronization
Selecting this option will allow to upload different data from the station unit to the meter
unit. The possible options are:

Synchronization of the actual time/date and the generated current

Uploading of test current results for Step / Contact voltage calculation

Uploading of earth resistance and ground resistivity results

Fig. 9: Synchronization screen

1. Press

or

keys to enter Settings menu

2. Select the item “Synchronize” with the  or  keys and press TEST key
3. Connect both units by using the PS/2-RS-232 supplied cable
4. Select one of the below options with the  or  keys and confirm with TEST key

TIME, CURRENT

Station’s time and date will be uploaded to the meter. Value
of generator current will be uploaded to the meter

STEP/CONTACT VOLT

Values of logged generator currents I

GEN

will be uploaded to

the Meter for calculation of Step voltage or Contact voltage

EARTH RESULT

Stored earth resistance or ground resistivity results in the
station will be uploaded to the meter

5. Press ESC key to exit and go back to the previous screen

CAUTION

 The main purpose of the Time/ Current synchronization is to enable a

correction of the step and contact voltage results after the test. During the
test the step and contact voltage results are calculated based on the I

GEN

set on the meter. After the test the obtained results can be updated with
the real generator currents I

GEN

measured at the same time with the

station. The stored U

STEP

and U

CONTACT

values are then corrected

according to the following formula:

SET

generated

actually

GEN

STEPold

STEPnew

I

I

U

U

)

_

(

SET

generated

actually

GEN

CONTold

CONTnew

I

I

U

U

)

_

(

 The synchronization is active for 24 h

 If date / time are changed on the meter or station the synchronization of

time and date will be lost. The current logger must be cleared before it can
proceed with measurements. Before clearing it you can download its
content to the meter



Advertising