Caution – HT instruments HT7051 User Manual

Page 25

Advertising
background image

HT2055

EN - 24

CAUTION

 When starting test the unit performs a preliminary check of the resistance

values of current probe (Rc) and voltage probe (Rp) stopping the test if
these values are assumed to be too high and giving the messages “Rc:
>2.0k

” and “Rp: >2.0k”. Decrease the resistance value wetting the

ground close to the probes and/or connect more probes in parallel

 High noise currents and voltages in earth could affect the measurement

results. In this case the tester displays the ”NOISE” warning


6 Press

MEM

key to save the result inside memory (see § 8.1)

CAUTION

To view stored ground resistivity results on PC they must be downloaded to
the meter unit first. To download the results select earth results in Synchronize
menu (see § 5.1.3). After the results are downloaded the stored data in
the station unit will be automatically deleted

































Advertising