4

With a steady grip, hold the receiver perpendicular to the position of a
known metallic conductor, e.g. above a location which was marked
during the site survey. The signal strength bargraph should show
zero (see paragraph 4.3.2). In doing so, the tip of the receiver should
touch the ground

5

Rotate the receiver (through its own axis) over this location until the
maximum signal strength is indicated (see paragraph 4.3.1.2)

Press the

button to begin measuring the depth

For automatic depth measure
(while working in TRANSMITTER
or PROBE mode)…

For making a rough estimate of
the depth (while working in
RADIO

or POWER GRID

mode)....

6

…the depth value is displayed (


The other steps can be skipped

…the herewith symbol is shown

continue from step 7

7

Move slowly to one side until the following symbol appears in the
display and an acoustic signal sounds:

8

Mark this spot, then move in the opposite direction to the other side of
the line until the symbol appears in the display again

Mark this spot as well, then measure the distance between the two
spots

9

Result:

Half the distance between the two spots corresponds

approximately to the depth of the line