4.2 CONNECTION AND INITIAL USE OF TRANSMITTER TX5000

4.2.1 Transmitter signals and operation modes
The type and strength of the output signal can be configured by the user as follows to
meet the specific requirements of either the line to be located or the site to be surveyed:

Symbol Signal

type

Pulsed signal
As it is more easily distinguished from other signals, the pulsed signal
is helpful for locating when there is interference within the frequency
range of the transmitter. This also helps to conserve the batteries

Depth measurements cannot be made using a pulsating signal

Continuous signal
This signal type has to be activated before a taking a depth
measurement

Symbol

Signal strength

Low output signal strength (0.1W)

Low signal strength conserves the batteries

High output signal strength (0.5W)

Symbol Operation

modes

Inductive connection
In this mode of operation the transmitter's signal is emitted through
the integrated antenna and is thereby inductively coupled with any
metallic lines located within a certain radius

Direct connection

In this mode of operation the signal is directly coupled with a metallic
line via the measurement cable which is connected to the jacks on
the front panel of the transmitter. Transmitter clamps, alligator clips or
power socket adapters (for example) may be used to connect the
measurement cable to the lines