HT instruments HT5000 User Manual

Page 30

Advertising
background image

HT-5000

EN - 29

6.2 TECHNICAL CHARACTERISTICS OF TRANSMITTER TX5000

Parameter Value

Transmitted power

(switchable)

0.1W / 0.5W

Frequency

32.768kHz

Power supply

6x1.5V batteries type IEC LR20

Battery life

40 hours (for intermittent use with alkaline
batteries, 20 °C)

Working temperature

• Operation

• Storage

according to IEC/EN60068-1
-20

÷ 55°C (-4 ÷ 131°F)

-30

÷ 70°C (-22 ÷ 158°F)

Category of measure

CAT II / CAT III 440V, CAT IV 300V

Size (LxWxH)

260 x 255 x 140mm (10.2 x 10 x 5.5)”

Weight

(included batteries)

1.7kg (3lb)

Mechanical protection

Dust and water protected

according to a IEC/EN60529
IP56

6.3 GENERAL

SPECIFICATIONS

Parameter Value

Sinusoidal vibrations

Peak acceleration
Frequency

According to IEC / EN 60068–2–6

20m/s

2

10Hz

÷150Hz

Free fall

Max. height (packaged)

According to IEC/EN60068-2-32
80cm (weight up to10kg)

Safety

IEC/EN61010-1

Protection class

III (according to IEC/EN61140)

Insulation

Double insulation

Relative humidity

max 93% at 30°C

6.4 ACCESSORIES
6.4.1 Standard

accessories

• Transmitter

TX5000

• 6x1.5V batteries IEC LR20

• Receiver

RX5000

• 10x1.5V batteries IEC LR06

• 2 cables R/B banana + alligator clip, 2m

• Carrying

bag

• 1 cable black banana + alligator clip, 10m

• User

manual

• 1 earth metal probe

6.4.2 Optional

accessories

• Flexi sonde set for locating non-metallic pipes – Cod GOK50-R

• Transmitter clamp, 100mm diameter for the inductive coupling – Cod. 820005314

• Set of cables (Shuko plug + cable with RJ11 + coax cable) – Cod. 890008852

Advertising