This instrument is a digital clamp-on earth resistance tester, and it is used in multi-

earthed systems. Can measure the earth resistance by simply clamping around the

earthed wires.

This instrument also equips AC current function to measure current up to 30A

same as our traditional leakage clamp meters.

A single earthing cannot be measured. (only for multiple-earthing system)

Wide measuring range (Auto-ranging)

Earth/ground resistance Max. 1200Ω

Min. resolution 0.01Ω

AC current

Max. 30A

Min. resolution 0.1mA

Noise check function

A function to detect current, which effects on an earth resistance measurement

and display the NOISE symbol on the LCD.

True RMS

Accurate true RMS readings of AC current with distorted waveform.

Auto power-off function

A function to prevent the instrument from being left turned on and conserve

battery power.

Data hold function

A function to freeze the measured value on the display.

Buzzer function

A function to give audible warning to the user when the measurement result is

10Ω or less.

Backlight function

A function to facilitate working at dimly lit areas.

Memory function

A function to save and display the measurement result.

Designed to following safety standard.

IEC61010-1 (CAT.IV 300V Pollution degree 2), IEC61010-2-032

This instrument is protected by double or reinforced insulation .