3 installation, 1 quick installation guide, Installation – Pyromation Series 642 User Manual

Page 7: Quick installation guide, 3installation

Advertising
background image

Series 642

Installation

Pyromation, Inc.

7

3

Installation

3.1

Quick installation guide

If the sensor is fixed then the unit can be fitted directly to the sensor.
If the sensor is to be mounted at a right angle to the cable gland, swap the dummy plug and cable
gland.
The device can be mounted directly on the wall. A mounting bracket is available for pipe mounting
(see Fig. 4). The illuminated display can be mounted in four different positions (

→ å 2):

Fig. 2:

Temperature field transmitter with sensor, 4 display positions, can be plugged-in in 90° steps

Fig. 3:

Turning the display

1.

Remove the cover clamp (Pos. 1).

2.

Unscrew the housing cover together with the O-ring (Pos. 2).

3.

Remove the display with retainer (Pos. 3) from the electronics module (Pos. 4). Adjust the
display with retainer in 90°stages to your desired position and rearrange it on the particular
slot in the electronics module.

4.

Then screw on the housing cover together with the O-ring. Mount the cover clamp.