3 site requirements, 4 the source and detector, 5 guidance tips for gas detector locations – Spectrex Quasar 900 Open-Path Gas Detection System User Manual

Page 38: 3 preparations for installation, Site requirements, The source and detector, Guidance tips for gas detector locations, Preparations for installation

Advertising
background image

SafEye

TM

Quasar 900 Gas Detector

26

Preparations for Installation

5.2.3 Site Requirements

The installation position of the SafEye system must take into account if the
gas being monitored is heavier or lighter than air, and the individual site
requirements. The site selected must give the Detector a direct view to the
Source. The mounting point for each item should be secure and stable with
minimal vibrations. Equipment should be either mounted in a position where
it cannot be knocked out of alignment, or guarded from physical impact.

5.2.4 The Source and Detector

The appropriate Detector should be selected for the length of open path to
be monitored. To allow for ageing of the Source and a reduction of the IR
signal due to adverse weather we recommend using a Detector that is not at
the limit of its operating range.

The open path between the Source and Detector and the immediate
surroundings should be kept clear of obscuration that might hinder the free
movement of air in the protected area or block the infrared beam.

5.2.5 Guidance Tips for Gas Detector Locations

Guidance Tips for Gas Detector locations in order to provide the best
detection coverage:

Below potential leak source for heavier than air gases

Above potential leak sources for lighter than air gases

Near to leak sources along the expected leak trajectory, taking into
account prevailing wind directions

Between leak source and potential ignition sources

In area with expected heavy fog, rain or snow, consider the effect of
long range installation and install the Detector at shorter range with the
maximum intensity model available.

5.3

Preparations for Installation

Installation should comply with local, national and international regulations
and norms as applicable to gas Detectors and approved electrical devices
installed in hazardous areas. The Detectors can be installed with general-
purpose common tools and equipment.

The System should include the following (in addition to this manual):

Detector unit - QR-X-11X (See Models and Types, page 8)

Source unit - QT-X-X1X (See Models and Types, page 8)

Two Tilt Mount Bases - P/N 888270

1 base is used for the Detector

1 base is used for the Flash Source

Commissioning Kit - P/N 888247