3 humidity, 4 salt and fog, 5 water and dust – Spectrex Xenon 700 SIL Open-Path Gas Detection System User Manual

Page 39: 6 shock and vibration, 7 electromagnetic compatibility (emc), Humidity, Salt and fog, Water and dust, Shock and vibration, Electromagnetic compatibility (emc)

Advertising
background image

TM 799200 Rev (C), January 2014

Environmental Specifications

27

4.4.3 Humidity

Designed to meet MIL-STD-810C, method 507.1, procedure IV relative
humidity of up to 95% for the operational temperature range.

4.4.4 Salt and Fog

Designed to meet MIL-STD-810C, method 509.1 procedure I. Exposure to a
5% salt solution for 48 hours.

4.4.5 Water and Dust

IP67 per EN60529

IP66 per EN60529

Dust:

Totally protected against dust

Liquids:

Protected against immersion between 15
cm and 1m in depth. Protected against

all water jets from all directions.

4.4.6 Shock and Vibration

Vibration:

Designed to meet MIL-STD-810C,
method 514.2, procedure VIII.

Mechanical Shock:

Designed to meet MIL-STD-810C,
method 516.1, procedure I.

4.4.7 Electromagnetic Compatibility (EMC):

This product is in conformance with EMC directive 89/336/EC.

Radiated Emission:

EN61000-6-3

Conducted Emission:

EN61000-6-3

Radiated Immunity:

EN61000-4-3

Conducted Immunity:

EN61000-4-6

ESD:

EN61000-4-2

Burst:

EN61000-4-4

Surge:

EN61000-4-5

Advertising