Communications Tab

The Communications tab displays the plug-in ports (locations) on the laptop required for communication to the mobile

transceiver and/or receiver and the GPS Before reading meters for the first time, it is important to ensure the correct

communication (Com/COM) ports have been set for the mobile transceiver and/or receiver to establish communication with

the ORS software application

OTEE:

N

The settings on the Communications tab are configured during system setup and, in most cases, do not need to be

changed Changes to the COM port fields should be made under the direction of Badger Meter Technical Support

When finished making changes to the settings on this screen, select OK and return to the reading cycle Select Cancel to

disregard any changes and return to the main menu

Figure 45: Settings screen – Communications tab

A typical ORION mobile reading system configuration (as shown in Figure 45) consists of an ORION mobile transceiver and/or

ORION mobile receiver and a built-in GPS receiver

ORION ME Transceiver

Com Port

The COM port for the ORION FHSS mobile transceiver is assigned automatically by Windows

based on the USB port it is connected to during initial system configuration

ORION CE/Permalog/Datamatic Receiver

Com Port

The COM port for the receiver is configured and assigned to the serial port The

default is COM1

No Data Received Timeout

The time (in milliseconds) before notification is given indicating the receiver is not

receiving endpoint data This field is filled with the default setting

No Packets Received Timeout The time (in milliseconds) before notification is given indicating the receiver is not

functioning correctly This field is filled with the default setting

SeTTINGS

Page 44

April 2014