Interval history, Historical interval file, Historical interval data – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 60

Advertising
background image

Interval History

The Interval History tab gives you the ability to collect an historical interval profile from the endpoint The data collected

becomes part of the route unload file and provides a water usage profile useful in discovering potential leaks, addressing

customer questions and/or resolving billing disputes

When ORS is used with ReadCenter Analytics or Analytics Mobile software, the reading data management software operator

has the option to create a work item to request and collect interval profile data from all ORION Migratable or Fixed Network

(in mobile mode) endpoints The work item initiates the interval profile collection automatically and does not require

manual intervention by the meter reader
As an alternative, the meter reader can initiate the interval profile extraction manually when a work item is not requested

by ReadCenter Analytics or Analytics Mobile, or when ORS is used with ReadCenter Data software See

"Requesting Interval

History Manually" on page 61

Whether the information is collected manually or as an automatic work item, it is transferred back to the reading data

management software operator as part of the route unload file

Historical Interval Data

ORS is capable of extracting historical data at the following intervals:

7 days/Week 14 days/ Two weeks

30 days/ Month

60 days/Two months

All readings stored in the endpoint

(Shorter months include extra days of readings, up to 30 )

(Up to 90 days of hourly readings or 2160 reads)

This chart shows the number of readings collected for meters set for hourly and fifteen minute readings:

Available Profile Data

Extraction Intervals

Hourly ReadsE:

1 Read per Hour

24 Reads per Day

15 Minute ReadsE:
4 Reads per Hour
96 Reads per Day

7 days

168 reads (24 x 7)

672 (96 x 7)

14 days

336 reads (24 x 14)

1344 (96 x 14)

30 days

720 reads (24 x 30)

2160 (96 x 22 5)

60 days

1440 reads (24 x 60)

2160 (96 x 22 5)

All/ 90 days

2160 reads (24 x 90)

2160 reads (96 x 22 5)

OTEE:

N

ORION Migratable or ORION Fixed Network (in mobile mode) endpoints are capable of holding up to 90 days of

readings, or 2160 hourly reads If the account is set up to read every 15 minutes—4 readings per hour—the data

extracted reflects four (4) readings per hour and reaches the maximum 2160 reads in 22 5 days (90 days / 4 =

22 5 days)

Historical Interval File Type

When work items are selected in ReadCenter Analytics or Analytics Mobile, historical interval data is saved as an xml

file when collected automatically or manually as part of route reading process, or during Quick Read on an account

that is part of the route file Historical interval data collected via Quick Read for an account that is not part of the

route file is saved as an endpoint-specific csv file

When work items are not selected in ReadCenter Analytics or Analytics Mobile, all interval data collected as part of

the route reading or during Quick Read is saved as endpoint-specific csv files

When ORS is used with ReadCenter Data, interval data collected is always saved as an endpoint-specific csv file

In all cases, the interval data files ( xml or csv) are included in the folder with the route unload files Historical interval

data that is returned to ReadCenter Analytics or Analytics Mobile is applied to an account’s history and viewable via the