Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 13

Advertising
background image

Trimble

®

Ranger™ Serial Repeater Programmer

Installation and Operation Manual

June 2009


SN Details

This screen will be displayed when you highlight a serial number and touch Show Details [S] on
the Program Repeater screen or press “S” on the keyboard.

Displays

Serial Number—Identifies the transmitter being repeated;

Meter Type—One of the following will appear:

RTR=Water meter using an RTR

®

;

ADE=Water meter using an ADE

®

;

GAS=Gas meter;

Unknown=Probably indicates a malfunctioning meter or a bad transmitter.

Reading—Last reading received from the transmitter;

Status—Tamper or leak; and

Misses—Number of times the repeater missed a meter reading from this transmitter. (Note: the
repeater listens for transmissions once per hour.)

Done [X]—Touch the button or press “X” on the keyboard to return to the Program Repeater
screen.

Diagnostic Tools

Touching Tools [T] on the Program Repeater screen or pressing “T” on the keyboard will take
you to the Diagnostic Tools screen.

The Diagnostic Tools screen will help you verify that the repeater is mounted in a place that
assures it will hear the transmissions it needs to re-transmit and be heard by a laptop on the
street.

12

Advertising
This manual is related to the following products: