PATLITE NHL User Manual

Page 59

Advertising
background image

59

4

4.10.2 Ping Monitor Configuration (Screen Numbers 21 to 24)

The following explains the Ping monitor setting method. A maximum number of 24 Ping monitors can be
registered.
Although the monitoring periods for screen numbers 1 through 20 is fixed at 60 seconds, the transmission
number in columns 21 through 24 can be changed (1 to 600 seconds).

[Setup Method]

1. Select the screen number between 21 to 24 to setup the Ping monitoring parameters.
2. Enter the IP address for a target to monitor.
3. Enter the device name for a target to monitor.
4. Set up the number of transmission times.
5. Set up the monitoring duration.
6. Set up the number of Ping requests within the duration.
7. Setup the condition for the Signal Tower when a monitor abnormality is detected.
8. To send an E-mail when a monitor abnormality occurs, set the E-mail Sending to "Active".

When the E-mail Sending is activated

Register the subject and the message text to transmit. Then, select the recipient for the E-mail Sending.

9. When using the TRAP transmission, set to "Active".

TRAP command transmitted when the TRAP is active

OID:

1.3.6.1.4.1.20440.4.1.6.1

Name: trapPatliteAlarmAdded

Fig. 4.10.3 Ping Monitor Setup Screen (Screen Number No. 21)