Keypad – Sterlco M2B+ Controller User Manual

Page 14

Advertising
background image

14 of 68

Keypad

Four keys, ‘Index’, ‘Up’, ‘Down’, and ‘Enter’ are used primarily to gain access to the menu
structure and modify the controller’s parameters and features. The remaining six keys are
used to direct the controller to start or stop a process.

Button

Function

Index

• Used to advance to one of the three setup menus.
• Used to advance to the next menu item when in a setup mode.
• Used in conjunction with the Down button to go back to a previous menu item when in a

setup mode.

• Used in conjunction with the Enter button at power-on to break into Factory mode.

Up

• Used to increment the current setpoint value while system is in the normal running mode.

Note that the rate speeds up when the key is held down.

• Used to increment the current parameter value when in a setup mode. Note that the rate

speeds up when the key is held down.

• If pressed when the oil unit is in the “PmpRev” Shutdown mode, the Vent Output and the

Alarm2 Output will be energized while the key is pressed. Use this function to reverse the
pump in order to purge the mold of hot oil.

Down

• Used to decrease the current setpoint value while the system is in the normal running

mode. Note that the rate speeds up when the key is held down.

• Used to decrease the current parameter value when in a setup mode. Note that the rate

speeds up when the key is held down.

• If pressed when the Index button is being held down, returns to the previous menu item

when in a setup mode.

Enter

• Used to select one of the three setup modes.
• Used to accept (save/write to EEPROM) the current indicated parameter value.
Note: No save/write occurs unless the Enter key is pressed before going to the

next/previous item or Setup mode is terminated.

• Used in conjunction with the INDEX key at power-on to enter into the Factory

mode.

Tune


• If no Autotune operation is in progress, this button starts an Autotune operation. If an

Autotune operation is in progress, pressing this button will immediately stop the Autotune
operation. While the Autotune is running, the “Autotune” message is displayed on the
LCD in place of the normal “Running” message.

• This key will not function if the Security Level is less than 3.
• This key will not function if the Ramp/Soak operation is in progress.
• This key will not function while in the Factory mode.

Run/Hold

• This key controls the Ramp/Soak process. If no Ramp/Soak operation is in progress, it starts

the Ramp/Soak operation. When Ramp/ Soak is running, this key puts the Ramp/Soak
operation into a hold condition. While the Ramp/Soak is running, the “Ramp/Soak”
message is displayed on the LCD in place of the normal “Running” message.

• This key will not function if the Security Level is less than 3.
• This key will not function if the Ramp/Soak operation is in progress.
• This key will not function while in the Factory mode.

Start

• When system is powered-on, the controller initializes and then displays the “[SYSTEM

OFF]” message on the LCD. The controller is not functioning at this point. Pressing this
START key enables all controller functions and lights the green power-on LED. After the
system has been started, the “[Running]” message is displayed on the LCD.

Stop

• Stops all controller functions and turns off the green power-on LED (overrides Remote

Start input). After the system has been stopped, the “Stopped” message is displayed on the
LCD.

• This key will override an existing Remote Start input switch closure.

Advertising