7-1 Electrical Specifications

General
Dimensions 5.5” X 9” X 4” (140 x 230 x 100)

Range of the Unit -45°F to 650°F (-42.7°C to 343°C)

Normal Operating Environment
Operating Temperature Range 0° C to 40° C (LCD Display up-to 50° C)

(-32°F to 104°F, display up to 122°F)

Humidity 0 to 95% RH (Non condensing)

Storage Environment
Storage Temperature Range -10° C to 95° C (50°C to 203°F)

Primary, Power Supply (Line Power)
Typical Supply Voltages 120VAC, 60Hz

Operating Range 85 to 150Vac 50/60 Hz, Single Phase

Consumption (Max/Typical) 15 Max/ 12 Watts Typ.

Connector Type/Model 5.8 mm Terminal Connector

Alarm Outputs
Mechanical relay Type (2 Outputs) 1A @120VAC INDUCTIVE (Alarm 1 tied to incoming

AC, Alarm 2 contacts only/no applied power).

External System Outputs
SCR/Triac Type 120Vac, 1A continuously @ 60° C for all output loads.

Snubbers to be applied externally by customer; there will
be no board mounted snubbers

System Output Variables Pump, Vent, Heater High/Low

Cool, Aux (Purge), Alarm 1, Alarm 2

User Interface
Keyboard Membrane Type, with Snap Dome Contacts

LCD Backlight LCD Brightness fixed/preset with Adjustable Pot.

Backlight will automatically turn off when there is 5
minutes of inactivity on the Keyboard

Display LCD Alphanumeric Display with Backlight