2-6 Menu Structure

The parameter menu structure is organized into three basic menus: Primary, Secondary, and
Secure. To access the menus, press the Index button until the menu label appears in the
second line of the LCD display. Additional menus display when an option is selected;
however, the options are non-functional unless the appropriate menu option or option board
has been installed. See the Menu Parameter Tables in the Appendix of this manual for more
information.

Continuing to press the Index button scrolls from menu to menu. Press the Enter button to
enter the menu, and use the Index button to scroll through the parameters of the menu. Once
you find the parameter that needs to be changed, use the Up and Down buttons to change the
parameter. Press the Enter button to accept the new value.

You can exit the setup menus by scrolling through the menu to its end or by pressing the
Alarm Silence button. The controller will automatically exit the setup menu if no buttons
have been pressed for more than one minute.

Primary Menu

The Primary menu includes all non-critical parameters for standard operation including but
not limited to standby mode, mold temperature, alarm trip points, ramp/soak settings, and
high heat.

Secondary Menu

The Secondary menu includes all non-critical parameters for optional equipment including
but not limited to degrees F/C, Alarm parameters, ramp/soak segments, remote setpoint
scaling, communication setup, and retransmission scaling.

Secure Menu

The Secure menu includes all critical parameters for setting up the controller including but
not limited to controller function, select either Water TCU or Oil TCU default values, flow
meter on/off, remote control probe on/off, pressure switch, high and low level, safety
thermostat on/off, output parameters, and scale limits.