2 electrical connections – Sterlco SMS Series Single Shaft Shredder User Manual

Page 29

Advertising
background image

GRN4-605

Chapter 3: Installation

29 of 93

SUSPENDED LOAD!

Falling loads can cause serious injury or death.
Only use a crane or forklift suitable for the weight and the

dimensions of the load.

Use suitable stopping equipment and pay attention to the gravity

center location.

DO NOT step under the suspended load.
Wear a safety helmet in addition to basic protective gear.

OVERTURNING OR FALLING MACHINE!

Serious injury or death can result.
If erecting the granulator over a pit, on a frame, or on a platform,

you MUST secure the machine by putting mounting screws through
the holes on the mounting pads (see Assembly Drawing). If
assembling the machine on solid ground, this safety device is not
always necessary.

3. Align the machine horizontally with the help of a suitable spirit level.

4. Do not use blocks to place underneath the machine; use metal strips to

prevent buckling of the base frame. Make sure that an even distribution
of weight is achieved on all the points of support.

3-2 Electrical Connections

Electrical connections should only be made by a qualified electrician.

DANGEROUS VOLTAGE! Touching live parts can lead to serious injury or death.
All work relating to the electricity of the machine may only be carried out by
trained electricians. Observe the currently effective EMC regulations.

Voltage, current, frequency, and protection are marked on the type plate. The voltage
tolerance is +/- 10%.

The electrical connection is to be carried out in accordance with the wiring diagram in the
terminal box for machines not pre-wired by the manufacturer.

NOTE: When making electrical connections, the regulations of the local electricity

authority must be followed. The required cable cross section required is
determined according to the rated capacity of the units
.