GRN4-605

Chapter 5: Maintenance

51 of 93

5. Clean the hexagon head socket of the cutter mounting screws (2) and the cover plates

mounting screws.

6. Loosen the cover plate mounting screws using a high quality Allen key (10 mm). Knock

the Allen key lightly with a hammer to loosen if necessary.

7. Take out the screws and cover plates.

8. Loosen the cutter adjusting screws for pulling and take them out.

9. Loosen the cutter mounting screws with Allen key (10 mm). Use a hammer to lightly

knock key if necessary.

10. Take out the cutter mounting screw and cutter.

WARNING! Danger of cutting caused by sharp cutters at all times—even when rotor is at
standstill. Serious Injury especially to the hands and fingers can occur. Wear protective
gloves!

















Mounting the Cutter Holders

1. Clean the cutter pocket and the cutter holder.

2. Insert cutter holder into the pocket.


NOTE: Cutter holder must slide in easily. Do not damage the cutter holder
surfaces with a hammer.

(1) Bed knife
(2) Knife mounting screws
(3) Knife holder
(4) Cover plates
(5) Knife adjusting screw for

pushing

(6) Cutter adjusting screw for

pulling

(7) Cover plate mounting

screws

1

2

6

5

3

4

7