4.4.4 Initial setting mode

The code "ch" represents input channels ( to ).

Character

PV screen
Auxiliary screen

Designation

Description

Initial value

1

□
□□□□

Select an initial
setting

Setting concerning initial setting

2

□
(□/
□)

Select an initial
setting channel

3

 ch


Set an input type

Multi-input model
□□□: Thermocouple K
□□□

: Thermocouple J

□□□: Thermocouple T
□□□: Thermocouple E
□□□

: Thermocouple R

□□□: Thermocouple S
□□□: Thermocouple B
□□□

: Thermocouple N

□□□: Thermocouple U
□□□: Thermocouple L
□□□

: Thermocouple WRe5-26

□□□: Thermocouple PR40-20
□□□: Thermocouple PL II
□□□

: Pt100

□□□: Pt100 (Display of the second decimal

place: -120.00 to 120.00)

□□□

: JPt100

□□□: JPt100 (Display of the second decimal

place: -120.00 to 120.00)

□□□

: Pt1000

□□□: Pt1000 (Display of the second decimal

place: -120.00 to 120.00)

□□□

: 0 to 1 VDC

□□□: 0 to 5 VDC
□□□: 1 to 5 VDC
□□□

: 0 to 10 VDC

□□□: 0 to 10 mVDC






For the 2ch side, not only the above inputs but the
following input can be selected as well:
: Potentiometer (selectable on the 2ch side only)

: Pt100, 4-wire type (selectable on the 1ch side

only)

Settable when an option is selected only.

The 2ch side cannot be selected when a 4-wire
type is selected.

