5. History

Revision A, January 8, 2004, by Ishihara and Sato

An operation flow was added.
1)

Cover: The model TTM-509 (tentative) was changed to "TTM-509.

2)

P7: The ▲ and ▼ in ⑦ and ⑧, which had been in the wrong order, were corrected.

3)

P9: A transition that occurs when the FUNC key is pressed in a priority screen was added.

4)

P10: The color of the I in the initial screen was changed from "orange" to "green."

5)

P11 to 12: A description was added for a case when banks were switched over with a DI.

6)

P13: (4) "SV start" was added.

7)

P16: In the description of the setting mode, "the ENT key … for a specific category" was changed to
"the MODE key... for a specific category."

8)

P17: In the bank setting mode, the screen was renamed. The  display of  was
switched to the auxiliary screen.

9)

P19: □ was changed to □.

10)

P19 to P24: Item 1, which was entirely designed for "Select the setting mode screen" was changed to
specific names such as "Select priority screen 0 setting."

11)

P28: The characters for D?F, D?P, SV? were changed.

12)

P29, 30: The parameters in the flow included an abnormal parameter. It was corrected.

13)

P38: A display setting for the operation mode was added. The initial value was corrected.

14)

P39: The bank setting mode and item 2 (auxiliary screen) were given a channel display.

15)

P40: Screens that cannot be set with a priority screen were described. A screen for the polygonal
line approximation mode.

16)

P41: The "4 to 20mA" was deleted from the input types. The aim was to give an external resistance
to 1 to 5V.

17)

P41: Input type: ,,, … Pt100, etc. -120.00 to 120.00 was added. The other input
type numbers were moved.

18)

P42: The PV filter setting of CH 1 and that of CH 2 were made identical.

19)

P42: Set a decimal place: Resistance bulb input: The  display was given an additional notation
when the input type was  only.

20)

P42, 43, 46, 48, 49, 51, 56, 59, and 60: A notation was added only when the input type was .

21)

P42: Set a PV filter: 0.00 was corrected to 0.0.

22)

P43: " turns off the display of the deviations" was added.

23)

P44: Precautions on resolution in analog input was added.

24)

P50: "Set an OUT? function" had not included the initial value from  to . It was then
added.

25)

P51: "Set a delay timer for event output 1" had not included the initial value. It was then added.

26)

P52: The name of  had been wrong. It was then corrected. Its description was corrected
too. "Heater abnormality" was added.

27)

P52, 53: Transmission function: : "MV (operation amount) output" was added.

28)

P54: "The target channel selections" in the SV2 function was set to _ and _ only.

Bank switchover was added to  in "Set a DI function."

The characters D?F, D?P, and SV? were changed.

29)

P55: The ASCII mode was added to the protocol for MODBUS.

In "Set a communications parameter," the specifications in the MODBUS enclosure were
changed.

"The communications delay is inactive with MODBUS was deleted.

In "Set a speed for communications 1" was deleted.