Modifiers, Modifiers -2 – Canon VB-C60 User Manual
Page 166
5-2
Modifiers
You can specify parameters using the "% characters" explained below.
* A runtime error will occur if the specified name does not match.
* If this modifier is not defined, "%" will be deleted.
%n
Reason for capture
(number)
0 (Test) | 1 (Contact input 1) | 2 (Contact input 2) |
33 (Interval timer) |
130 (Motion detection [Area 1]) | 131 (Motion detection [Area 2]) |
132 (Motion detection [Area 3]) | 133 (Motion detection [Area 4])
%N
Reason for capture
(character string)
<External device input name (alphanumeric characters)>|<Motion detection area
name (1/2/3/4)>|
Null (null character / interval timer test)
%X
Width of image
Number of pixels in horizontal direction
%Y
Height of image
Number of pixels in vertical direction
%C
Camera number
1
%D
Camera name
Setting for [Camera Name (alphanumeric characters)]
%P
Pan position
-179.99 ~ 180.00
%T
Tilt position
-179.99 ~ 180.00
%Z
Zoom position
0.1 ~ 300.00
%V
Camera server
VB-C60
%y
Year of capture time
2001 ~ 2031
%m
Month of capture time
1 ~ 12
%d
Day of capture time
1 ~ 31
%w
Day of week of capture
time
0 ~ 6 (Sunday through Saturday)
%H
Hours of capture time
00 ~ 23
%M
Minutes of capture time
00 ~ 59
%S
Seconds of capture
time
00 ~ 59
%s
Milliseconds of capture
time
000 ~ 999
%z
Time zone of capture
time
-1200 ~ +1300
%a
Weekday name of
capture time
Sun | Mon | Tue | Wed | Thu | Fri | Sat
%b
Month name of capture
time
Jan | Feb | Mar | Apr | May | Jun | Jul | Aug | Sep | Oct | Nov | Dec
%h
Host name