5.5.3 Vertical Concentric connection

Straight adapters are available for either 60/100mm or 80/125mm systems.
IMPORTANT!
Using the concentric adapter set (see photo), the standard two-pipe
connection can be changed into a concentric connection.
5. Seal the open air supply connections in the appliance with the sealing

cap delivered with the set (item C in photo).

6. Remove the sealing ring around the flue discharge in the appliance, as

shown above.

7. In its place, fit the sealing ring ø 116 x 110 mm (item B in photo).
8. Fit the adapter (item A in photo) on the flue discharge.

5.5.4 80/125mm Concentric flue system