Technical specifications – Atmos Energy HE26 User Manual

Page 50

Advertising
background image

10. TECHNICAL SPECIFICATIONS

Appliance category

B13; B33; C13; C 33; C 43; C53; C63; C83

Gas inlet pressure

20 mbar

Suitable for gas

II

2

H

3

P

Technical data

InterSystem HE 26

CH
Heat power input (gross)*

kW

8.0 – 30.3

Heat power input (net)*

kW

7.2 – 27.3

Heat output at 80/60°C*

kW

7.0 – 26.2

Heat output at 50/30°C*

kW

7.7 – 26.8

Max. CH water pressure

bar

2.5 (see note 1)

CH operating pressure

bar

1 – 2 (see note 2)

Max. CH water temperature

°C

90

Other data
Gas consumption

m

3

/h

0.85 - 3.25

Electrical data
Mains voltage

V

230

Protection class

IP44 (B(.)=IP20)

Consumed power: full load

W

105

Consumed power: partial load

W

40

Consumed power: standby

W

2.4

Overall dimensions and weight
Height mm

810

Width mm

450

Depth mm

270

Weight kg

39


*The maximum CH power is set to 50% of the highest value at the factory (see Setting CH power).
Notes 1 - Safety discharge valve is 3 bar.
2 – Min pressure 1 bar ( expansion vessel pre-charge is 1 bar).


50

Advertising