Troubleshooting continued – Water Inc HP-RO-1000 User Manual

Page 12

Advertising
background image

Limited Flow at Drinking Water Faucet

1. Turn off water supply to system at saddle valve.

2.

3. Unscrew the blue cap at the base of the storage tank to

expose air valve. Use a small air compressor or bicycle
pump to add air to the storage tank. This will force the
water out of the storage tank through the faucet. Continue
to add air until no more water comes out of the faucet.

4. Turn off the drinking water faucet.

5. Using an air pressure gauge, adjust the pressure in the

storage tank to 5–7 psi.

6. Replace the blue cap.

7. Open the saddle valve until it comes to a stop. Let the

approximately 33 pounds. If performance has not improved,
call Technical Support.

Sudden Return of Taste and Odor

If shortly after complete servicing, noticeable taste and odors
return, contact Technical Support.

If you are experiencing a problem not listed in this manual,
shut off the water supply at the saddle valve and close the tank
valve. Call Technical Support at 800-322-9283.

TROUBLESHOOTING continued

12 •

HP-RO-1000 Undersink Reverse Osmosis System