3. Mounting the Faucet

A. Pre-assemble the base. The rubber washer should be

in place below the base. The two toggle bolts should be
inserted through the base and the rubber washer. The
bolts are screwed into the spring-loaded toggle.

B. Place the base assembly over the hole in the sink. The

two toggles should pass through the hole far enough to
spring fully open. If they are not open, unscrew the bolt
until the toggle moves down to clear the sink.

C. Look down through the base for this step. Before

tightening the bolts, determine the correct rotation of the

off from the bolt heads. Use Figure 5 to help determine
the best position for your installation.
Through the hole in the base, hold the toggle in position
while tightening the bolt. The spring loaded toggle
will contact the bottom of the counter top and hold in
position. Do not fully tighten. Repeat for second toggle
bolt.

Tighten the two bolts evenly. DO NOT OVERTIGHTEN.
Tighten only far enough to prevent the base from
rotating when the faucet is rotated in place.

D. Attach large diameter 3/8" (red) drain tube to the larger

long enough to reach the drain clamp in Step 7.

E. Locate the 1/4" red brine tube from the right side of the

system head assembly. Route the tube through the
faucet base and connect to small barb on the faucet.
Make certain that the tube is not kinked or stressed
once the head assembly is mounted.

F.

quick connector onto end of threads.

G. Wet end of 3/8" blue tube. Push into bottom of

connector. Tug gently to be sure connection is
complete. This tube should be long enough to reach the
top right side of the RO Assembly.

H. Check that the O-ring is in place on the faucet. Feed

the remaining 3/8" tubes through the base. Hold the

left) while pushing down. The faucet will drop into the
base. Push down on the faucet and rotate forward (to

seated and the faucet held securely in position.

I. Insert the spout into the top opening. Hold in position

and screw the collar onto the base.

NOTE: If the faucet handle is not in the correct

position, remove the faucet, loosen the toggle
bolts and reposition the base. Tighten the
toggle bolts. Then reinstall the faucet.

Base

Black Rubber

Washer

Folds Upward

A

Figure 3

B

Base

Black Rubber

Washer

Will Spring Open

O-ring Seat

Figure 4

C

Handle Faces This Direction

45°

Notch For Faucet

Blades Must Be Held

When Tightening

Notch For Faucet

Figure 5

G

D

E

F

Figure 6

INSTALLATION continued

O-ring

4 • HP-RO-1000 Undersink Reverse Osmosis System