Performance data, Housepure hp-ro-1000, State of california – Water Inc HP-RO-1000 User Manual

Page 15: Water treatment device certicate number

Advertising
background image

HP-RO-1000 Undersink Reverse Osmosis System • 15

Performance Data

Important Notice: Read this performance data and compare
the capabilities of this system with your actual water treatment
needs. It is recommended that before installing a water
treatment system, you have your water supply tested to
determine your actual water treatment needs.

This system has been tested according to NSF/ANSI 58 for the

reduction of the substances listed below. The concentration
for the indicated substances in water entering the system
was reduced to a concentration less than or equal to the

NSF/ANSI 58.

NOTE: Substances that may be reduced are not

necessarily in your water. Filter must be maintained
according to manufacturer’s instructions, including

to the system that is available to the user as reverse osmosis
treated water under operating conditions that approximate
typical daily usage. The tested recovery rating is 27.40%.

to the membrane portion of the system that is available to the
user as reverse osmosis treated water when the system is
operated without a storage tank or when the storage tank is
bypassed.

against NSF/ANSI Standard 42 and 58 for the reduction of

substances listed in the table above.

State of California

Department of Public Health

Water Treatment Device

Certicate Number

Date Issued: October 24, 2011

Trademark/Model Designation

Replacement Elements

2097

11 -

PW-RO75R

(RO Membrane)

PW-S2500R (Pre Filters)
PW-C5000R (Pre Filters)
PW-C2500R (Post Filter)

Manufacturer: Pentair Residential Filtration, LLC

The water treatment device(s) listed on this certificate have met the testing requirements pursuant to Section
116830 of the Health and Safety Code for the following health related contaminants:

Cysts

Turbidity

Arsenic (pentavalent)

1

Barium

Cadmium
Chromium (hexalent)
Chromium (trivalent)
Copper

Fluoride

Lead

Radium 226/228

Selenium

None

Microbiological Contaminants and Turbidity

Inorganic/Radiological Contaminants

Organic Contaminants

Do not use where water is microbiologically unsafe or with water of unknown quality, except that systems certied
for cyst reduction may be used on disinfected waters that may contain lterable cysts.

1

Claims for arsenic reduction shall only be made on water supplies maintaining detectable residual free chlorine at the

reverse osmosis (RO) system inlet. Water systems using an in-line chlorinator should provide a minimum of 1 minute
chlorine contact time before the RO system.

1250 gal service cycle

Rated Service Capacity:

24.8 gpd

Rated Service Flow:

Conditions of Certification:

HousePure HP-RO-1000

Substance

Concentration

Maximum

Permissible

Product Water

Concentration

Reduction

Requirements

Average

Reduction

Standard 58

Arsenic V

0.050 mg/L ± 10%

0.010 mg/L

97.6%

Barium

10.0 mg/L ± 10%

2.0 mg/L

96.7%

Cadmium

0.03 mg/L ± 10%

0.005 mg/L

98.2%

Chromium III

0.3 mg/L ± 10%

0.1 mg/L

97.6%

Chromium VI

0.3 mg/L ± 10%

0.1 mg/L

97.0%

Copper

3.0 mg/L ± 10%

1.3 mg/L

98.8%

Cysts

Minimum 50,000/mL

99.95%

99.99%

Fluoride

8.0 mg/L ± 10%

1.5 mg/L

96.2%

Lead

0.15 mg/L ± 10%

0.010 mg/L

99.0%

Radium

226/228

27pCi/L ± 10%

5pCi/L

80%

Selenium

0.10 mg/L ± 10%

0.05 mg/L

98.0%

Total Dissolved

Solids

750 mg/L ± 40 mg/L

187 mg/L

94.9%

Turbidity

11 mg/L ± 1 NTU

0.5 NTU

99.1%

Standard 42
Chlorine

2 mg/L

>=50%

93.0%

Production Rate: 24.83 gpd

Testing was performed under standard laboratory conditions,
actual performance may vary.

The HP-RO-1000 is Tested and Certified by NSF International

HousePure HP-RO-1000