Hp insight control virtual machine management, Hp smart update manager – HP Systems Insight Manager User Manual

Page 135

Advertising
background image

When an Onboard Administrator is discovered, the enclosure that it resides in is created. If this enclosure
is daisy chained to other c-class enclosures, then these enclosures are also created. By default, daisy chained
enclosures are displayed as c7000 enclosure models. As a result, when c7000 and c3000 enclosures are
daisy chained, and the Onboard Administrator is discovered, the c3000 Tower Model enclosure is displayed
as a c7000 enclosure. To ensure that the daisy chained enclosures are displayed accurately, you must
discover the Onboard Administrator on each of these enclosures.
-------------------------------------------------------------
To correctly identify the xw25p Blade Workstation, you must install Insight Management Agents 7.4.

-------------------------------------------------------------
To associate the Cisco Gigabit Ethernet Switch Module with the HP BladeSystem enclosure it is inserted in,
you must update the HP Insight Management Agents to 7.3 or later on at least one blade in the enclosure.

-------------------------------------------------------------

If you have licensed a system for HP Insight Control power management and receive the following error
message while attempting to view the last data collection status on the System Page for the system,
Unable to communicate with Management Processor <mpname> in server <servername>
because the Management Processor does not have a serial number and(or) network
address. Please re-identify the Management Processor and try again.

, then there

might be a problem with duplicate iLOs associated with the system. Use the All Management Processors
view and identify the iLOs associated with the server. There is one iLO with its name being the IP address
of the iLO and another iLO with the serial number of the iLO as its system name. Deleting the iLO with no
IP address recorded resolves the issue.
-------------------------------------------------------------

After discovering new servers and their iLO 2 management processors using Reports

Insight Power

Manager

, the task wizard indicates the server is not compatible with Insight Power Manager.

Solution: Insight Power Manager requires an association to exist between the iLO management processor
and the server before compatibility can be determined. If you attempt to use the Insight Power Manager tool
before this has been determined, you encounter this issue.

Select the iLO 2 from the system list and execute Tools

Identify Systems to re-execute the Insight

Power Manager compatibility check.

or

Wait for 15 minutes for Insight Power Manager's periodic system management to re-determine
compatibility. After compatibility has been verified, this problem should not reoccur.

-------------------------------------------------------------

After applying an iLO Select or Advanced license to the iLO 2 using its user interface, Refresh Data is
clicked in Insight Power Manager to collect new power history data and a message appears indicating the
iLO 2 has no license.

Solution: Systems Insight Manager must re-identify the iLO 2 to detect the presence of the new license. Select
Tools

Identify Systems to re-identify the iLO 2 or wait for Systems Insight Manager's periodic identification

cycle to complete. You can check the status of Systems Insight Manager's awareness of iLO 2 license
assignment selecting Deploy

License Manager.

HP Insight Control virtual machine management

After you have selected the Install Linux PSP or ESX agents and Register VM host options in a Configure
or Repair Agents task for ESX 3.5 U4 or later, the VM-host registration task fails because the system shows
as Not Responding in Vcenter. Vcenter takes about five minutes for a system to reach a Normal status and
therefore fails when Systems Insight Manager tries to register the VM host. Re-run the VM-host registration
task at a later time when the server is in a Normal state in Vcenter.

HP Smart Update Manager

If you are receiving an HP Smart Update Manager Connection Error or Discovery Failed message in the
StdOut Task Results for Initial ProLiant Support Pack Install, SSH Install, or Configure or Repair Agents, follow
the following troubleshooting tips:

Ensure your workstation does not have an existing connection to the admdin$ share on the target IP
address. If it does, it prevents HP Smart Update Manager from connecting to the remote server’s share
because Windows only allows one connection from a client to a server’s share. This can be checked

HP Insight Control virtual machine management

135