Procedure B-14 Issue with changing and saving the address of an Ignite server

1.

From the CLI, go to the Tools directory under the Systems Insight Manager install directory on Windows
and under /var/opt/mx/tools on Linux and HP-UX.

2.

Run mxtool -mf <tool XML> -x force' where <tool XML> for each TDef is as follows:

iux_tools.xml

swm-msa-tools.xml

swm-ssa-tools-up.xml

swm-ssa-tools.xml

hpux\iux_tools.xml

hpux\swm-msa-tools.xml

HP MIBs

The LinkUp and LinkDown traps in IF-MIB.mib are redundant traps; these are also present in rfc1215.mib.
As per the current framework, the redundant traps are not allowed in Systems Insight Manager Traps with
same name

.

Change the loading of MIBs. The IF-MIB.mib is loaded first and then the RFC1215.mib. The IF-MIB.mib
will be listed in mibcore.list and rfc1215 in preload.list. By doing this the LinkUp and linkDown
traps from IF-mib.mib will only be registered with Systems Insight Manager and in Options

EventsFile

Name

. The RFC1215 file will only show four traps Cold Start, Warm Start, Authentication Failure, egp....

-------------------------------------------------------------
Do not rename, move, or delete MIB files from the MIBs directory after they are registered.

Solution: For a MIB file to be listed as registered, the MIB file must reside in the MIBs directory.

Onboard Administrator

When an Onboard Administrator system is deleted, health status of the bare metal server systems remain
stale. ProLiant OA must be rediscovered to obtain updated health status of the bare metal server systems.

OpenSSH

OpenSSH installation fails on a Windows XP SP3 system.

Solution: Verify that the Network access: Sharing and security model for local accounts under Local
Policies

Security Options is set to Classic - local users are authenticate as themselves.

Performance

When running Systems Insight Manager in an environment that contains a large number of ProLiant systems
running the WMI-based Insight Agents, the completed job output in Tasks & Logs

View Task Results

might exceed several thousand files.
Solution: This can result in Systems Insight Manager consuming large amounts of memory, task page interface
slowdown, or out of memory errors.
If this behavior is noted, the following workaround can be implemented to alleviate the consumption of
memory and disk space. The workaround adjusts the retention values for completed tasks and can be altered
as desired to reduce resource consumption.

NOTE:

This fix only applies to Systems Insight Manager instances which are managing a large number

of servers (maximum 5000) using WMI.

Add the following script to the MX.PROPERTIES file located in the Microsoft Windows directory \Program
Files\HP\Systems Insight Manager\config

or in the Linux and HP-UX directory

/etc/opt/mx/config

:

MX_JOB_MAX_COMPLETED_JOBS_PER_TASK=3

Recommended value is 3 for greater than 1500 systems

MX_JOB_MAX_COMPLETED_JOB_AGE=7

Recommended value is 7 for greater than 1500 systems

MX_JOB_KEEP_RUN_NOW_HOURS=8

Recommended value is 8 for greater than 1500 systems

After the MX.PROPERTIES file has been modified, restart the Systems Insight Manager service to initiate