Modifying rcu options (change rcu option), Figure 32 rcu option pane, Figure 33 rcu settings parameter list (rcu option) – HP XP Continuous Access Software User Manual

Page 60: 32 rcu option pane, 33 rcu settings parameter list (rcu option), Modifying rcu options, Change rcu option)

Advertising
background image

60

Continuous Access XP for the XP1024/XP128

Min.Path: Minimum number of paths required for each RCU connected to the current MCU

Activity: Number of concurrent initial copy operations

MIH Time: Time value for the remote I/O (RIO) missing interrupt handler (MIH)

Path Watch: Time for monitoring blockade in the Fibre Channel paths on the MCU side

Modifying RCU options (Change RCU Option)

Use the RCU Options pane to modify RCU options set when you registered the RCU. When the RCU

Option pane is opened with the Change RCU Option command, all fields are blank. You must fill in the

fields you need to modify; it is not necessary to fill in all fields. Fields left blank keep settings made for the

registering RCU operation.
RCU options apply to all CU images of the current MCU and all RCUs connected to the MCU.

Figure 32

RCU Option pane

For further information about the RCU Option pane, see ”

Registering RCUs (Add RCU)

” on page 56.

1.

In the CU number/Port tree on the RCU Operation pane, ensure that the correct CU image is selected.

2.

From the MCU/RCU list, click the RCU you want to modify.

3.

Right-click, click RCU Operation, and click Change RCU Option. The RCU Option pane appears.

4.

Modify RCU options. When the RCU Option pane is open, all fields are blank. Fill in the fields you

want to modify.

5.

Click Set to set the modifications. The list changes to the RCU Settings Parameter list (RCU Option)

view. Click Cancel to cancel all modifications you made.

NOTE:

After being set, options can be modified and canceled (see

Modifying parameters and

deleting settings

” on page 66).

6.

Click Apply on the Continuous Access XP main pane to apply the modification to the disk array.

When modifications are set (the RCU Option pane closes), the MCU/RCU list changes to the RCU Settings

Parameter list (RCU Option).

Figure 33

shows the items om the RCU Settings Parameter list (RCU Option).

Figure 33

RCU Settings Parameter list (RCU Option)

S/N and SSID: RCU serial number and SSID

M-R Path: Channel type

Min.Path: Minimum number of paths required for each RCU connected to the current MCU

Activity: Number of concurrent initial copy operations

Advertising