182 Troubleshooting

Pair-Port Number Mismatch

Specified port in the remote array is

physically disconnected from the local

array.

Ensure that you specified the correct

remote array port. Correct the port

number if necessary.
Ensure that the local and remote arrays

are connected by cables to each other.

If the arrays are not by cables, and retry

the operation.
Ensure that the topology settings of

ports on the local and remote arrays

are correct.

Pair-Port Type Mismatch

Specified remote array port is not

configured as an RCU target port.

Ensure that the remote array port is

configured as an RCU target port.

Communication Failed

Local array is connected to the remote

array successfully, but a logical

communication timeout occurred.

Ensure that the remote array port and

network relay devices (for example,

cables and switches) are properly

configured and functioning.

Logical Blockade

Failure occurred at a local array port.

Repair the port status on the local array.

Failure occurred at a remote array port. Repair the port status on the remote

array. After that, delete the path using

the Delete Path or Delete DKC

command, and add the path and

remote array again using the Add Path

or Add DKC command.

Failure occurred in the path relay

equipment.

Repair the path relay equipment. After

that, delete the path using the Delete

Path or Delete DKC command, and add

the path and remote array again using

the Add Path or Add DKC command.

Connection cable is physically broken.

Replace the broken cable. After that,

delete the path using the Delete Path or

Delete DKC command, and add the

path and remote array again using the

Add Path or Add DKC command.

Program Error

Program error detected.

Delete the path using the Delete Path or

Delete DKC command, and add the

path and remote array again using the

Add Path or Add DKC command.

<blank>

Path was not established.

Delete the failed path. You might need

to change the minimum paths setting or

delete the remote array to delete the

path. After deletion finishes, add the

path and remote array using the Add

Path or Add DKC command.

Table 34

Troubleshooting problems with status of logical paths (continued)

Pair status

Description

Corrective action