Blocked ilo ports, Troubleshooting alert and trap issues, Incorrect authentication code – HP Integrated Lights-Out 3 User Manual

Page 217

Advertising
background image

4.

Click Advanced in the Proxy server section.

5.

Enter the iLO IP address or DNS name in the Exceptions box.

6.

Click OK to save the changes.

Blocked iLO ports

Solution: iLO communicates through several configurable TCP/IP ports. If these ports are blocked,
the administrator must configure the firewall to allow for communications on these ports. For
information about viewing and changing the iLO port configuration, see

“Configuring iLO access

settings” (page 39)

.

Troubleshooting alert and trap issues

Table 12 (page 217)

lists the alerts and traps that might occur.

Table 12 Alerts

Description

Alert

This trap is generated when you click the Send Test Alert button on the
Administration

→Management page in the iLO web interface.

Test Trap

The server lost power.

Server Power Outage

The server was reset.

Server Reset

A remote user login attempt failed.

Failed Login Attempt

This is an error condition that is not predefined by the hard-coded MIB.

General Error

The circular log has been overrun.

Logs

The state of the Security Override Switch changed (On/Off).

Security Override Switch

Changed: On/Off

The server could not power on because of insufficient power.

Rack Server Power On Failed

The server was forced to power on manually despite reporting insufficient
power.

Rack Server Power On Manual

Override

The name of the rack was changed.

Rack Name Changed

The listed user logged in through a browser.

Browser login: <user>

The listed user logged out through a browser.

Browser logout: <user>

The listed user logged in to the Remote Console.

Remote Console login: <user>

A user closed the Remote Console.

Remote Console Closed

The listed user started a firmware upgrade.

iLO Firmware upgrade started by

<user>

Unable to receive HP SIM alarms (SNMP traps) from iLO

Solution: A user who has the Configure iLO Settings privilege must connect to iLO to configure
SNMP trap parameters. When you are connected to iLO, make sure that the correct alert types
and trap destinations are enabled on the Administration

→Management page in the iLO web

interface.

Incorrect authentication code

When you use a Mozilla browser, you might receive an incorrect authentication code error message,
which indicates that the public or private key pair and certificate used to initiate the browser SSL
session has changed. This error message might occur when you do not use a customer provided
certificate because iLO generates its own self-signed certificate each time it is rebooted.

Troubleshooting alert and trap issues