3

FINE TUNE - sense

Resolver Sense:
Azimuth

>true<

Elevation inv
Pol Angle inv

1

2

3

4

5

6

(not used)

toggles the highlighted parameter

between ‘true’ and ‘inv’

(not used)

moves the highlight box to the next field

in the current menu

Current Mode Tracking

Control State Local

Beac Freq 11.452000 GHz

Beac Level -10.05 dB

El Angle 25.37

o

Az Angle 210.50

o

Pol Angle 27.4

o

Function

Press EN to accept sense settings

Next

Field

Change

Resolver

Sense

Home

Standby

puts the antenna control system into

STANDBY mode and skips to the HOME

menu

skips to the Home (root) menu



Path

HOME - FUNCTION - SYSTEM SETUP -

MENU KEY 6 (x2) - ENTER


or

From Models or Configuration

SYSTEM SETUP - MENU KEY 6 (x2) - ENTER



Description

This menu allows

the “sense” of the Azimuth, Elevation and

Polarisation resolvers to be inverted. This is necessary to
allow for different mounting arrangements for the resolvers.


Use Menu Key 6 to step the edit highlight through the three
angles. Use Menu Key 4 (Change Resolver Sense) to toggle
between “true” and “inv.”


Pressing ENTER accepts the settings and moves on to the
“FINE TUNE - Offsets” menu. (see next page)