Installation Instructions

GAS REQUIREMENTS

DRYER GAS SUPPLY CONNECTION

GAS SUPPLY

A 1/8” National Pipe Taper thread plugged

tapping, accessible for test gauge connection,

must be installed immediately upstream of the

gas supply connection to the dryer. Contact

your local gas utility should you have questions

on the installation of the plugged tapping.

Supply line is to be 1/2” rigid pipe and equipped

with an accessible shutoff within 6 feet of, and

in the same room with, the dryer.

Use pipe thread compound appropriate for

natural or LP gas or use PTFE tape.

Connect flexible metal connector to dryer and

gas supply.

The installation must conform with local codes,

or in the absence of local codes, with the

National Fuel Gas Code, ANSI Z223.1/NFPA 54,

or the Natural Gas and Propane Installation

Code, CSA B149.1.

IN THE COMMONWEALTH OF

MASSACHUSETTS

This product must be installed by a licensed

plumber or gas fitter.

When using ball-type gas shut-off valves, they

shall be the T-handle type.

A flexible gas connector, when used, must not

exceed 3 feet.

3/8

NPT MALE THREAD GAS SUPPLY

NOTE: Add to vertical dimension

the distance between cabinet

bottom to floor.

4

7

ø

16

” (11.27 cm)

1

19

ø

32

(4.05 cm)

ADJUSTING FOR ELEVATION

Gas clothes dryers input ratings are based on

sea level operation and need not be adjusted

for operation at or below 2000 ft. elevation. For

operation at elevations above 2000 ft., input

ratings should be reduced at a rate of 4 percent

for each 1000 ft. above sea level.

Installation must conform to local codes and

ordinances or, in their absence, the NATIONAL

FUEL GAS CODE, ANSI Z223.

You must use with this dryer a flexible metal

connector (listed connector ANSI Z21.24 / CSA 6.10).

The length of the connect shall not exceed 3 ft.

- Explosion Hazard

WARNING

• Use a new CSA International approved flexible

gas supply line. Never reuse old flexible

connectors.

• Install a shut-off valve.
• Securely tighten all gas connections.
• If connected to LP gas, have a qualified person

make sure gas pressure does not exceed 13”

water column.

• Examples of a qualified person include: licensed

heating personnel, authorized gas company

personnel, and authorized service personnel.

• Failure to do so can result in death, explosion,

or fire.