Installation instructions – GE GFDR480GFWW User Manual

Page 21

Advertising
background image

21

Installation Instructions

ELECTRICAL CONNECTION

INFORMATION FOR ELECTRIC DRYERS

- Fire Hazard

WARNING

Use a new UL-listed 240V 30 amp dryer power supply

cord with closed ring terminals or spade terminals with

upturned ends.
Use a UL-listed strain relief.
Disconnect power before making electrical

connections.
Connect neutral wire (white or center wire) to center

terminal.
Ground wire (green or bare wire) must be connected to

green ground connector.
Connect remaining two supply wires to remaining two

terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical

shock.

For electrical connections using a

power cord:

ELECTRICAL CONNECTION

INFORMATION FOR ELECTRIC DRYERS
For direct wire connections:

- Fire Hazard

WARNING

Use 10 gauge copper wire.
Use a UL-listed strain relief.
Disconnect power before making electrical

connections.
Connect neutral wire (white or center wire) to center

terminal.
Ground wire (green or bare wire) must be connected to

green ground connector.
Connect remaining two supply wires to remaining two

terminals.
Securely tighten all electrical connections.
Replace the terminal block cover.
Failure to do so can result in death, fire or electrical

shock.

GROUNDING INSTRUCTIONS

For a grounded, cord-connected dryer: This dryer

must be grounded. In the event of a malfunction

or breakdown, grounding will reduce the risk

of electric shock by providing a path of least

resistance for electric current. This dryer uses a

cord having an equipment-grounding conductor

and a grounding plug. The plug must be plugged

into an appropriate outlet that is properly installed

and grounded in accordance with all local codes

and ordinances.

WARNING

Improper connection of the

equipment-grounding conductor

can result in a risk of electrical shock. Check with a

qualified electrician, or service representative or

personnel, if you are in doubt as to whether the

appliance is properly grounded. DO NOT modify the

plug on the power supply cord. If it will not fit the

outlet, have a proper outlet installed by a qualified

electrician.
SAVE THESE INSTRUCTIONS

GROUNDING INSTRUCTIONS

For a permanently connected dryer: This

dryer must be connected to a grounded metal,

permanent wiring system, or an equipment-

grounding conductor must be run with the circuit

conductors and connected to the equipment-

grounding terminal on the appliance.

WARNING

Improper connection of the

equipment-grounding conductor

can result in a risk of electrical shock. Check with a

qualified electrician, or service representative or

personnel, if you are in doubt as to whether the

appliance is properly grounded.
SAVE THESE INSTRUCTIONS

Advertising