Installation Instructions

TEST FOR LEAKS

Never use an open flame to test for gas leaks.

Check all connections for leaks with soapy solution

or equivalent.
Apply a soap solution. The leak test solution must

not contain ammonia, which could cause damage

to the brass fittings.
If leaks are found, close the valve, retighten the

joint and repeat the soap test.

Open Gas

Valve

Ensure proper

ground exists

before use.

Ground

Screw

ELECTRICAL CONNECTION

INFORMATION FOR GAS DRYERS (cont.)

The dryer must be electrically grounded in

accordance with local codes, or in the absence of

local codes, with the National Electrical Code, ANSI/

NFPA 70 or Canadian Electrical Code, CSA C22.1
This appliance must be supplied with 120V, 60Hz, and

be connected to a properly grounded branch circuit

protected by a 15 or 20 amp circuit breaker or time

delay fuse. If electrical supply provided does not meet

these requirements, it is the owner’s responsibility to

have a licensed electrician install a properly grounded

3-prong outlet.

If local codes permit an external ground wire (not

provided) may be added by attaching to the green

ground screw on the rear of the dryer, and to a

grounded metal cold water pipe or other established

ground.

ELECTRICAL CONNECTION

INFORMATION FOR GAS DRYERS

- Electrical Shock Hazard

WARNING

Plug into a grounded 3 prong outlet.
DO NOT remove ground prong.
DO NOT use an adapter.
DO NOT use an extension cord.
Failure to do so can result in death, fire or electrical

shock.