Installation Instructions

EXHAUSTING THE DRYER

EXHAUST SYSTEM CHECKLIST

HOOD OR WALL CAP

Terminate in a manner to prevent back drafts or entry

of birds or other wildlife.

Termination should present minimal resistance to

the exhaust airflow and should require little or no

maintenance to prevent clogging.

Wall caps must be installed at least 12” above ground

level or any other obstruction with the opening

pointed down.

Never vent the dryer out of the roof.

SEPARATION OF TURNS

For best performance, separate all turns by at least

4 ft. of straight duct, including distance between last

turn and dampened wall cap.

SEALING OF JOINTS

All joints should be tight to avoid leaks. The male end

of each section of duct must point away from the

dryer.

Duct joints should be made air- and moisture-tight

by wrapping the overlapped joints with duct tape or

aluminum tape.

Do not assemble ductwork with any fasteners

that extend into the duct. These fasteners can

accumulate lint, creating a potential fire hazard.

Horizontal runs should slope down towards the

outdoors 1/4” per foot.

Provide an access for inspection and cleaning of

the exhaust system, especially at turns and joints.

Exhaust system shall be inspected and cleaned at

least once a year.

INSULATION

Ductwork that runs through an unheated area or is

near air conditioning should be insulated to reduce

condensation and lint buildup.

TOOLS AND MATERIALS YOU WILL NEED TO INSTALL EXHAUST DUCT

ˆ

Phillips-head screwdriver

ˆ

Duct tape or duct

clamp

ˆ

Rigid or UL-listed

flexible metal 4” (10.2

cm) duct

ˆ

Drill with 1/8” drill bit

(for bottom venting)

ˆ

Hacksaw

ˆ

Vent hood

- Fire Hazard

WARNING

This dryer MUST be vented to the outdoors.
Use only 4” rigid metal ducting for the home

exhaust duct.
Use only 4” rigid metal or UL-listed dryer transition

duct to connect the dryer to the home exhaust.
DO NOT use a plastic vent.
DO NOT exhaust into a chimney, kitchen exhaust,

gas vent, wall, ceiling, attic, crawl space, or

concealed space of a building.
DO NOT install a screen in or over the exhaust duct.
DO NOT use duct longer than specified in the

exhaust length table.
Failure to follow these instructions can result in

death or fire.