Installation Instructions

Using exhaust longer than specified length will:

• Increase the drying times and the energy cost.
• Reduce the dryer life.
• Accumulate lint, creating a potential fire

hazard.

The correct exhaust installation is YOUR

RESPONSIBILITY.
Problems due to incorrect installation are not

covered by the warranty.
The MAXIMUM ALLOWABLE length of the exhaust

system depends upon the type of duct, number

of turns, the type of exhaust hood (wall cap) and

all conditions noted on the chart.

EXHAUST LENGTH

RECOMMENDED MAXIMUM LENGTH

Exhaust Hood Types

Recommended

Use only for short- run

installations

No. of 90º

Rigid

Rigid

Elbows

Metal

Metal

0

90 Feet

60 Feet

1

60 Feet

45 Feet

2

45 Feet

35 Feet

3

35 Feet

25 Feet

4

25 Feet

15 Feet

4” DIA

4”

2

1

ø

2

4” DIA

4” DIA

Internal elbows added for side or bottom vent

conversions must be included in the total elbow

count.

Any elbow greater than 45° should be treated as a

90° elbow.

Two 45° elbows will be treated like one 90° elbow.

For the side exhaust installations, add one 90°

elbow to the chart.

The total vent system length includes all the

straight portions and elbows of the system

(transition duct included).

EXHAUST LENGTH