2.12 STARTUP PROCEDURES
To achieve optimal performance and image clarity, the
following procedures should be accomplished in the order
presented, each time the CNVD-T3 is to be placed into
operation:

a. Install batteries per paragraph 2.2.2.

b. Turn on the CNVD-T3 by pressing the POWER

button. Wait approximately 6 seconds until the
system begins imaging.

c. Select from the Main Menu either the HAND or

CLIPON setting as described in paragraph 2.13.10.

d. Select from the Main Menu either the MCAL (Manual

Calibration) or ACAL (Automatic Calibration) setting
as described in paragraph 2.13.8.

e. Adjust the brightness setting to a comfortable

viewing level as described in section 2.9.

f. Adjust the gain setting to a comfortable viewing level

as described in section 2.10.

g. While looking through the eyepiece at an object at

least 10m away, rotate the objective focus ring until
the best (sharpest) image is obtained.


Advertising