3-4

NOTE

A slight, audible hissing sound may be noticed
during the venting process as air escapes from the
purge port.

(3) Gently rock the purge screw back and forth to

vent the CNVD-T3.

CAUTION

Over-tightening the purge screw may damage the
CNVD-T3 housing.

(4) Reinstall the purge screw and tighten until

snug. Once snug, turn the purge screw an
additional 1/8 turn to tighten.

e. Poor or degraded image.

(1) Perform a calibration per paragraph 2.13.3.
(2) Remove night adaptive filter / demist shield, if

installed. Clean eyepiece and objective lens.

(3) Inspect the night adaptive filter / demist shield

for dirt, grime, scratches, and cracks. Clean
and/or replace, if necessary.

(4) Replace existing batteries with fresh batteries.