Turbo Action 70600 CHEETAH E-SHIFT Controller User Manual

Page 13

Advertising
background image

13

Turn Function Switch knob clockwise until the right
LED display position digits read 10. This position sets
the Pit Road First Shift RPM to within 100 RPM
Fig. #12.

Factory Default = 3000 RPM (Fig. #12)

Program Position #10:
Do the same as Position #1.

Turn Function Switch knob clockwise until the right
LED display position digits read 11. This position sets
the Pit Road Second Shift RPM to within 100 RPM
Fig. #13.

Factory Default = 3000 RPM (Fig. #13)

Program Position #11:
Do the same as Position #1.

Turn Function Switch knob clockwise until the right
LED display position digits read 12. This position sets
the Pit Road FallBack RPM, which is the RPM that the
controller resets on engine deacceleration Fig. #14.

Factory Default = 1500 RPM (Fig. #14)

Program Position #12:
Do the same as Position #1.

Turn Function Switch knob clockwise until the right
LED display position digits read 13. This position sets
the Number of Cylinders 2, 4, 6, 8 or 10 Fig. #15.

Factory Default = 8 Cylinders (Fig. #15)

Program Position #13:
Push either 1000’s or 100’s Button to advance the
number of cylinders.

POSITION #11: Pit Road Second (2-3) Shift RPM

3 0 1 0

10K 1K 100 POS. POS.

Fig. #12

3000 RPM

3 0 1 1

10K 1K 100 POS. POS.

Fig. #13

3000 RPM

1 5 1 2

10K 1K 100 POS. POS.

Fig. #14

1500 RPM

8

1 3

10K 1K 100 POS. POS.

Fig. #15

8 Cylinders

POSITION #13: Number of Cylinders

POSITION #10: Pit Road First (1-2) Shift RPM

POSITION #12: Pit Road FallBack RPM

Position #10, #11 and #12 for CHEETAH Electronic Valve Bodies Only.